In this following post we have shared an overview and download link of MRI in Practice 5th Edition PDF. Read the quick review below and download the PDF by using links given at the end of the post. We have uploaded these PDF and EPUB files to our online file repository so that you can enjoy a safe and blazing-fast downloading experience.
MRI in Practice continues to be the number one reference book and study guide for the registry review examination for MRI offered by the American Registry for Radiologic Technologists (ARRT). This latest edition offers in-depth chapters covering all core areas, including: basic principles, image weighting and contrast, spin and gradient echo pulse sequences, spatial encoding, k-space, protocol optimization, artefacts, instrumentation, and MRI safety.
Table of Contents
ToggleFeatures of MRI in Practice 5th Edition PDF:
- The leading MRI reference book and study guide.
- Now with a greater focus on the physics behind MRI.
- Offers, for the first time, equations and their explanations and scan tips.
- Brand new chapters on MRI equipment, vascular imaging and safety.
- Presented in full color, with additional illustrations and high-quality MRI images to aid understanding.
- Includes refined, updated and expanded content throughout, along with more learning tips and practical applications.
- Features a new glossary.
Table of Contents:
- Chapter 1 Basic principles 1
- Introduction 1
- Atomic structure 2
- Motion in the atom 2
- MR active nuclei 4
- The hydrogen nucleus 5
- Alignment 6
- Net magnetic vector (NMV) 8
- Precession and precessional (Larmor) frequency 10
- Precessional phase 13
- Resonance 13
- MR signal 18
The free Induction decay(FDI) signal 20
Pulse timing parameters 22 - Chapter 2 Image weighting and contrast 24
- Introduction 24
- Image contrast 25
- Relaxation 25
- T1 recovery 26
- T2 decay 27
- Contrast mechanisms 31
- Relaxation in different tissues 32
- T1 contrast 36
- T2 contrast 40
- Proton density contrast 41
- Weighting 42
- Other contrast mechanisms 51
- Chapter 3 Spin echo pulse sequences 58
- Introduction 58
- RF rephasing 59
- Conventional spin echo 65
- Fast or turbo spin echo FSE/TSE) 68
- Inversion recovery (IR) 78
- Short tau inversion recovery (STIR) 82
- Fluid attenuated inversion recovery (FLAIR) 84
- Chapter 4 Gradient echo pulse sequences 89
- Introduction 89
- Variable flip angle 90
- Gradient rephasing 91
- Weighting in gradient echo pulse sequences 94
- Coherent or rewound gradient echo 106
- Incoherent or spoiled gradient echo 109
- Reverse-echo gradient echo 113
- Balanced gradient echo 119
- Fast gradient echo 122
- Echo planar imaging (EPI) 122
- Chapter 5 Spatial encoding 128
- Introduction 128
- Mechanism of gradients 129
- Gradient axes 134
- Slice-selection 135
- Frequency encoding 142
- Phase encoding 145
- Bringing it all together – pulse sequence timing 152
- Chapter 6 k-space 158
- Introduction 158
- Part 1 – what is k-space? 159
- Part 2 – how are data acquired and how are images created from this data? 165
- Part 3 –some important facts about k-space 184
- Part 4: how do pulse sequences fill k-space? 197
- Part 5: options that fill k-space 199
- Chapter 7 Protocol optimization 209
- Introduction 209
- Signal-to-noise ratio (SNR) 210
- Contrast-to-noise ratio (CNR) 226
- Spatial resolution 232
- Scan time 237
- Trade-offs 238
- Protocol development and modification 238
- Chapter 8 Artefacts 242
- Introduction 242
- Phase mismapping 243
- Aliasing 253
- Chemical shift artefact 261
- Out-of-phase signal cancellation 265
- Magnetic susceptibility artefact 269
- Truncation artefact 272
- Cross-excitation/cross-talk 273
- Zipper artefact 275
- Shading artefact 276
- Moiré artefact 277
- Magic angle 279
- Equipment faults 280
- Flow artefacts 280
- Flow-dependent (non-contrast enhanced) angiography 298
- Black-blood imaging 303
- Phase contrast MRA 304
- Chapter 9 Instrumentation 311
- Introduction 311
- Magnetism 313
- Scanner configurations 315
- Magnet system 318
- Magnet shielding 326
- Shim system 328
- Gradient system 330
- RF system 337
- Patient transport system 343
- Computer system and graphic user interface 344
- Chapter 10 MRI safety 346
- Introduction (and disclaimer) 346
- Definitions used in MRI safety 347
- Psychological effects 350
- The spatially-varying static field 351
- Electromagnetic (radiofrequency) fields 357
- Time-Varying Gradient Magnetic Fields 363
- Cryogens 365
- Safety tips 367
- Additional resources 368
About the Author:
CATHERINE WESTBROOK, Senior Lecturer and Course Leader, MSc Magnetic Resonance Imaging (MRI), Anglia Ruskin University, Cambridge, UK.
JOHN TALBOT, Senior Lecturer, MSc Magnetic Resonance Imaging (MRI), Anglia Ruskin University, Cambridge, UK.
You Mighlt like other medical book:
Youmans and Winn Neurological Surgery: 4 – Volume Set 8th Edition PDF
Mulholland & Greenfield’s Surgery: Scientific Principles and Practice 7th Edition PDF
Download MRI in Practice 5th Edition PDF Free:
You can easily download MRI in Practice 5th Edition PDF by clicking the link given below. If the PDF link is not responding, kindly inform us through comment section. We will fixed it soon.
DMCA DISCLAIMER: This sites complies with DMCA digital copyright laws.
NOTE: Here i need you attention to some of the important words about this article. This post was share just for educational purpose and to help medical students, post graduates and professors. This Site only educate our visitors about the materials. Medicscenters.com do not share the copyright materials on this site. The Link which is provide as found/ taken from the others websites. we highly encourage our visitors to buy the materials from its original authors. More over we do not store any kind of illegal link in our medicscenter.com server. We always follow the legal DMCA policy. There is no copyright materials share on medicscenter.com, We only offer the materials which are free on internet. This website is educational purpose and if there is any copyright materials against DMCA policy, who want to remove the materials kindly contact us on email [email protected].
Leave a Reply